Blackout-BOX
Make your heating system blackout-ready! Our new blackout box, which acts as an uninterruptible power supply UPS for your Hargassner heating system in the event of a power failure, is perfectly matched to our Nano-PK & Smart-PK pellet boilers and Neo-HV & Smart-HV wood log boilers.
Blackout-BOX
- Capacitance 2,232 Wh
- Pellets: 2 – 3 days* incl. filling of day hopper
- Wood logs: 2 – 4 burn-ups = 2 – 3 days*
- Also ideal for use as a camping battery or similar
- Has four USB 3.0 ports and two USB-C; 12 V connection
- 230 V connection options for e.g. fridge or freezer
- Can be combined with an emergency power generator for extended power outages
* Running times may vary depending on the connected loads (e.g. HV pump, hot water circulation, etc.)
Info table on power consumption
For the use of emergency power generators (on-site)
For the following boiler types and accessories
Type | Nominal voltage | Mains frequency | Connection | Ø Power consumption P avg | Max. Power consumption P max | Large consumers |
---|---|---|---|---|---|---|
Nano-PK 6-32 | 230V AC +-10% | 50Hz +-5% | 1-phase | 0.1 kW | 2 kW | Suction turbine |
Classic 9-60 and HSV | 230V AC +-10% | 50Hz +-5% | 1-phase | <0.15 kW | 2 kW | old ignition 1050 W |
Smart-PK 17-32 | 230V AC +-10% | 50Hz +-5% | 1-phase | <0.15 kW | <0.5 kW |
Deviations from these values are possible depending on the accessories and pumps connected to the boiler.
Heat circuit and buffer circuit pumps must also be included in the calculation. Read the technical data on the pump nameplate
Type | Nominal voltage | Mains frequency | Connection | Ø Power consumption P avg | Max. Power consumption P max | Large consumers |
---|---|---|---|---|---|---|
Neo-HV | 230V AC +-10% | 50Hz +-5% | 1-phase | <0.15 kW | <0.5 kW | Ceramic ignition 300 W |
Smart-HV | 230V AC +-10% | 50Hz +-5% | 1-phase | <0.15 kW | <0.15 kW | |
Deviations from these values are possible depending on the accessories and pumps connected to the boiler.
Heat circuit and buffer circuit pumps must also be included in the calculation. Read the technical data on the pump nameplate.
Type | Nominal voltage | Mains frequency | Connection | I L1 max | I L2 max | I L3 max | Ø Power consumption P avg | Max. Power consumption P max |
---|---|---|---|---|---|---|---|---|
Eco-HK 20-60 | 400 V AC +-10% | 50 Hz +-5% | 3-phase | 4 A | 1.2 A | 1.2 A | 0.3 kW | 1 kW |
Eco-HK 70-120 | 400 V AC +-10% | 50 Hz +-5% | 3-phase | 4 A | 1.2 A | 1.2 A | 0.3 kW | 1 kW |
Eco-HK 130-230 | 400 V AC +-10% | 50 Hz +-5% | 3-phase | 4.6 A | 1.8 A | 1.9 A | 0.3 kW | 2.1 kW |
Eco-HK 250-330 | 400 V AC +-10% | 50 Hz +-5% | 3-phase | 4.6 A | 1.8 A | 1.9 A | 0.3 kW | 2.1 kW |
Eco-PK same as Eco-HK + 1.5 kW suction turbine
Deviations from these values are possible depending on the accessories and pumps connected to the boiler.
Heat circuit and buffer circuit pumps must also be included in the calculation. Read the technical data on the pump nameplate
extraction system motor
Motors 3-phase 400 V | normal | maximum (<1s) |
---|---|---|
Suction turbine | 1.5 kW | |
Eco-HK 20-60 extraction system motor up to 5 m 0.18 kW | 0.4 kW | 1.5 kW |
Eco-HK 20-60 >5 m 0.25 kW | 0.5 kW | 1.9 kW |
Motor stoker Eco-HK/PK 20-120 0.25 kW | 0.6 kW | 1.9 kW |
Motor stoker Eco-HK/PK 130-330 0.45 kW | 0.7 kW | 2.9 kW |
Motor connection auger Eco-HK 20-60 / extraction system Eco-HK 70-120 0.37 kW | 0.5 kW | 1.9 kW |
Motor connection auger Eco-HK 70-120 0.55 kW | 0.7 kW | 3.4 kW |
Return pump only Eco-HK/PK 130 and above | 0.2-0.4 kW |
Type | Power consumption |
---|---|
Leister fan ignition | max. 1,500 W |
Ceramic ignition ignition coil | 300 W |