Back to the accessories

For pellet and log boilers

Blackout
BOX

Learn more
Ansicht Blackout-BOX USV schräg rechts | Hargassner

Blackout-BOX

Make your heating system blackout-ready! Our new blackout box, which acts as an uninterruptible power supply UPS for your Hargassner heating system in the event of a power failure, is perfectly matched to our Nano-PK & Smart-PK pellet boilers and Neo-HV & Smart-HV wood log boilers.

Blackout-BOX

  • Capacitance 2,232 Wh
  • Pellets: 2 – 3 days* incl. filling of day hopper
  • Wood logs: 2 – 4 burn-ups = 2 – 3 days*
  • Also ideal for use as a camping battery or similar
  • Has four USB 3.0 ports and two USB-C; 12 V connection
  • 230 V connection options for e.g. fridge or freezer
  • Can be combined with an emergency power generator for extended power outages

* Running times may vary depending on the connected loads (e.g. HV pump, hot water circulation, etc.)

Info table on power consumption

For the use of emergency power generators (on-site)

For the following boiler types and accessories

Pellet boiler
Type Nominal voltage Mains frequency Connection Ø Power consumption P avg Max. Power consumption P max Large
consumers
Nano-PK 6-32 230V AC +-10% 50Hz +-5% 1-phase 0.1 kW 2 kW Suction turbine
Classic 9-60 and HSV 230V AC +-10% 50Hz +-5% 1-phase <0.15 kW 2 kW old ignition 1050 W
Smart-PK 17-32 230V AC +-10% 50Hz +-5% 1-phase <0.15 kW <0.5 kW

Deviations from these values are possible depending on the accessories and pumps connected to the boiler.
Heat circuit and buffer circuit pumps must also be included in the calculation. Read the technical data on the pump nameplate

Wood log boiler
Type Nominal voltage Mains frequency Connection Ø Power consumption P avg Max. Power consumption P max Large
consumers
Neo-HV 230V AC +-10% 50Hz +-5% 1-phase <0.15 kW <0.5 kW Ceramic ignition 300 W
Smart-HV 230V AC +-10% 50Hz +-5% 1-phase <0.15 kW <0.15 kW

Deviations from these values are possible depending on the accessories and pumps connected to the boiler.
Heat circuit and buffer circuit pumps must also be included in the calculation. Read the technical data on the pump nameplate.

Eco-HK and Eco-PK
Type Nominal voltage Mains frequency Connection I L1 max I L2 max I L3 max Ø Power consumption P avg Max. Power consumption P max
Eco-HK 20-60 400 V AC +-10% 50 Hz +-5% 3-phase 4 A 1.2 A 1.2 A 0.3 kW 1 kW
Eco-HK 70-120 400 V AC +-10% 50 Hz +-5% 3-phase 4 A 1.2 A 1.2 A 0.3 kW 1 kW
Eco-HK 130-230 400 V AC +-10% 50 Hz +-5% 3-phase 4.6 A 1.8 A 1.9 A 0.3 kW 2.1 kW
Eco-HK 250-330 400 V AC +-10% 50 Hz +-5% 3-phase 4.6 A 1.8 A 1.9 A 0.3 kW 2.1 kW

Eco-PK same as Eco-HK + 1.5 kW suction turbine

Deviations from these values are possible depending on the accessories and pumps connected to the boiler.
Heat circuit and buffer circuit pumps must also be included in the calculation. Read the technical data on the pump nameplate

extraction system motor

Motors 3-phase 400 V normal maximum (<1s)
Suction turbine 1.5 kW
Eco-HK 20-60 extraction system motor up to 5 m 0.18 kW 0.4 kW 1.5 kW
Eco-HK 20-60 >5 m 0.25 kW 0.5 kW 1.9 kW
Motor stoker Eco-HK/PK 20-120 0.25 kW 0.6 kW 1.9 kW
Motor stoker Eco-HK/PK 130-330 0.45 kW 0.7 kW 2.9 kW
Motor connection auger Eco-HK 20-60 / extraction system Eco-HK 70-120 0.37 kW 0.5 kW 1.9 kW
Motor connection auger Eco-HK 70-120 0.55 kW 0.7 kW 3.4 kW
Return pump only Eco-HK/PK 130 and above 0.2-0.4 kW
Ignitions
Type Power consumption
Leister fan ignition max. 1,500 W
Ceramic ignition ignition coil 300 W

In your region