Airflow-M
5–20 kW
BASIC

Compact & simple
Energy efficiency class A++ / A+++

  • Ideal for existing installations
  • Individual components can be freely positioned
  • Control of the entire heating system
  • 7" colour touch display
  • Intelligent hybrid function

Heat pump BASIC

Simple stepless control of your heat pump

The “BASIC” indoor unit is designed for simple control of the heating system. The entire refrigeration circuit of the heat pump system is located in the outdoor unit. The indoor unit controls the room heating and cooling as well as the production of hot water.

Note: Shipping of the Hargassner Airflow-M heat pump will start in February 2025.

  • Copeland ScrollTM Inverter Compressor with Wide Power Modulation
  • Environmentally friendly refrigerant R452B (GWP 676)
  • 7" colour touch display
  • Easy to use: App & web app along with smart home
  • Perfect combination thanks to intelligent hybrid function
  • Efficient operation down to -25°C
  • Flow temperature of up to 65°C possible
  • Heating and cooling as standard
  • Quick and easy installation
  • Modern design
  • High weather resistance thanks to powder-coated aluminum housing
  • Quiet operation with only 46 dB according to EN 12102
  • Very good energy efficiency with a SCOP of up to 4.76
  • Energy efficiency class up to A+++
Included in delivery: Infinitely variable high-efficiency pump, outdoor temperature sensor, flow sensor, 3/4'' overflow valve

Our heat pump in detail

Specifics
of Airflow-M BASIC

Outdoor units
heat pump
Airflow-M BASIC

In order to generate sustainable energy for your home, you always need two separate units with a monobloc heat pump concept. These consist of an indoor unit and an outdoor unit with an output ranging from 5 to 20 kW, which contains the entire refrigerant circuit, including the evaporator, compressor, condenser and expansion valve.
Our 3D model allows you to view the outdoor unit of your heat pump from all angles. With the help of augmented reality (AR), you can even place the heat pump in its future location for a more accurate representation. Our innovative 3D visualisation offers a glimpse into the future of planning!

Open 3D model in a new window

Indoor unit
heat pump
Airflow-M BASIC

With this indoor unit, controlling your entire heating system – whether for heating or cooling – is effortless thanks to the large touch display. The BASIC unit, which is mounted on the wall, can be placed freely according to customer requirements and is also ideal for existing installations.

Technical
details

Modulation range
Heating capacity at A-7W35*
Heating capacity at A-7W55*
SCOP at 35 / 55°C *
Efficiency of ETAs at 35 / 55°C *
Energy efficiency class at 35 / 55°C *
Sound power level normal / night **
Sound pressure level at a distance of 5m / 8m ***
Supply voltage
Supply voltage
Max. power consumption
Dimensions of outdoor unit
(W x H x D)
Dimensions of indoor unit
(W x H x D)
Weight outdoor unit / indoor unit
Hot water tank
kW
kW
kW
%
dB(A)
dB(A)
V / Hz
A
kW
mm
mm
kg
    AFM 5 – BASIC
    Modulation range 2 - 5 kW
    Heating capacity at A-7W35* 4.98 kW
    Heating capacity at A-7W55* 4.77 kW
    SCOP at 35 / 55°C * 4.09 / 3.25
    Efficiency ETAs at 35 / 55°C * 160.5 / 127.1 %
    Energy efficiency class at 35 / 55°C * A++ / A++
    Sound power level normal / night ** 54 / 51 dB(A)
    Sound pressure level at 5m / 8m distance *** 32/ 28 dB(A)
    Supply voltage 230 / 50 V / Hz
    Connection current 15 A
    Max. power consumption 5.32 kW
    Dimensions of outdoor unit
    (W x H x D)
    1150 x 860 x 515 mm
    Dimensions of indoor unit
    (W x H x D)
    315 x 450 x 132 mm
    Weight of outdoor unit / indoor unit 129 / 8.2 kg
    Hot water tank -
    AFM 7 – BASIC
    Modulation range 2 - 7 kW
    Heating capacity at A-7W35* 5.42 kW
    Heating capacity at A-7W55* 5.18 kW
    SCOP at 35 / 55°C * 4.12 / 3.23
    Efficiency ETAs at 35 / 55°C * 161.8 / 126 %
    Energy efficiency class at 35 / 55°C * A++ / A++
    Sound power level normal / night ** 55 / 52 dB(A)
    Sound pressure level at 5m / 8m distance *** 33 / 29 dB(A)
    Supply voltage 230 / 50 V / Hz
    Connection current 15 A
    Max. power consumption 5.32 kW
    Dimensions of outdoor unit
    (W x H x D)
    1150 x 860 x 515 mm
    Dimensions of indoor unit
    (W x H x D)
    315 x 450 x 132 mm
    Weight of outdoor unit / indoor unit 129 / 8.2 kg
    Hot water tank -
    AFM 9 – BASIC
    Modulation range 2 - 9 kW
    Heating capacity at A-7W35* 6.62 kW
    Heating capacity at A-7W55* 6.45 kW
    SCOP at 35 / 55°C * 4.21 / 3.34
    Efficiency ETAs at 35 / 55°C * 165.5 / 130.6 %
    Energy efficiency class at 35 / 55°C * A++ / A++
    Sound power level normal / night ** 46 / 43 dB(A)
    Sound pressure level at 5m / 8m distance *** 24 / 20 dB(A)
    Supply voltage 230 / 50 V / Hz
    Connection current 15 A
    Max. power consumption 5.32 kW
    Dimensions of outdoor unit
    (W x H x D)
    1390 x 860 x 590 mm
    Dimensions of indoor unit
    (W x H x D)
    315 x 450 x 132 mm
    Weight of outdoor unit / indoor unit 148 / 8.2 kg
    Hot water tank -
    AFM 12 – BASIC
    Modulation range 3 - 12 kW
    Heating capacity at A-7W35* 7.89 kW
    Heating capacity at A-7W55* 7.79 kW
    SCOP at 35 / 55°C * 4.20 / 3.54
    Efficiency ETAs at 35 / 55°C * 165.1 / 138.7 %
    Energy efficiency class at 35 / 55°C * A++ / A++
    Sound power level normal / night ** 48 / 45 dB(A)
    Sound pressure level at 5m / 8m distance *** 26 / 22 dB(A)
    Supply voltage 400 / 50 V / Hz
    Connection current 3 x 12 A
    Max. power consumption 7.4 kW
    Dimensions of outdoor unit
    (W x H x D)
    1390 x 860 x 590 mm
    Dimensions of indoor unit
    (W x H x D)
    315 x 450 x 132 mm
    Weight of outdoor unit / indoor unit 148 / 8.2 kg
    Hot water tank -
    AFM 14 – BASIC
    Modulation range 4 - 14 kW
    Heating capacity at A-7W35* 9.57 kW
    Heating capacity at A-7W55* 9.33 kW
    SCOP at 35 / 55°C * 4.73 / 3.38
    Efficiency ETAs at 35 / 55°C * 186.1 / 132.2 %
    Energy efficiency class at 35 / 55°C * A+++ / A++
    Sound power level normal / night ** 50 / 47 dB(A)
    Sound pressure level at 5m / 8m distance *** 28 / 24 dB(A)
    Supply voltage 400 / 50 V / Hz
    Connection current 3 x 12 A
    Max. power consumption 7.4 kW
    Dimensions of outdoor unit
    (W x H x D)
    1350 x 1505 x 585 mm
    Dimensions of indoor unit
    (W x H x D)
    315 x 450 x 132 mm
    Weight of outdoor unit / indoor unit 210 / 8.2 kg
    Hot water tank -
    AFM 16 – BASIC
    Modulation range 5 - 16 kW
    Heating capacity at A-7W35* 12.05 kW
    Heating capacity at A-7W55* 11.95 kW
    SCOP at 35 / 55°C * 4.76 / 3.41
    Efficiency ETAs at 35 / 55°C * 187.2 / 133.5 %
    Energy efficiency class at 35 / 55°C * A+++ / A++
    Sound power level normal / night ** 52 / 49 dB(A)
    Sound pressure level at 5m / 8m distance *** 30 / 26 dB(A)
    Supply voltage 400 / 50 V / Hz
    Connection current 3 x 12 A
    Max. power consumption 7.4 kW
    Dimensions of outdoor unit
    (W x H x D)
    1350 x 1505 x 585 mm
    Dimensions of indoor unit
    (W x H x D)
    315 x 450 x 132 mm
    Weight of outdoor unit / indoor unit 212 / 8.2 kg
    Hot water tank -
    AFM 18 – BASIC
    Modulation range 5 - 18 kW
    Heating capacity at A-7W35* 13.01 kW
    Heating capacity at A-7W55* 12.87 kW
    SCOP at 35 / 55°C * 4.71 / 3.35
    Efficiency ETAs at 35 / 55°C * 185.2 / 131.0 %
    Energy efficiency class at 35 / 55°C * A+++ / A++
    Sound power level normal / night ** 53 / 50 dB(A)
    Sound pressure level at 5m / 8m distance *** 31 / 27 dB(A)
    Supply voltage 400 / 50 V / Hz
    Connection current 3 x 12 A
    Max. power consumption 7.4 kW
    Dimensions of outdoor unit
    (W x H x D)
    1350 x 1505 x 585 mm
    Dimensions of indoor unit
    (W x H x D)
    315 x 450 x 132 mm
    Weight of outdoor unit / indoor unit 212 / 8.2 kg
    Hot water tank -
    AFM 20 – BASIC
    Modulation range 5 - 20 kW
    Heating capacity at A-7W35* 13.78 kW
    Heating capacity at A-7W55* 13.65 kW
    SCOP at 35 / 55°C * 4.69 / 3.23
    Efficiency ETAs at 35 / 55°C * 184.4 / 126.3 %
    Energy efficiency class at 35 / 55°C * A+++ / A++
    Sound power level normal / night ** 54 / 51 dB(A)
    Sound pressure level at 5m / 8m distance *** 32 / 28 dB(A)
    Supply voltage 400 / 50 V / Hz
    Connection current 3 x 12 A
    Max. power consumption 7,4 kW
    Dimensions of outdoor unit
    (W x H x D)
    1350 x 1505 x 585 mm
    Dimensions of indoor unit
    (W x H x D)
    315 x 450 x 132 mm
    Weight of outdoor unit / indoor unit 212 / 8.2 kg
    Hot water tank -

    *according to EN 14511 (medium climate) | **according to EN 12102 | ***Free field installation

    Target group
    & possible areas of application

    5 steps to your ideal heat pump

    Heating with
    air & water

    01

    Order brochure

    02

    Heat capacity

    03

    External & internal module

    04

    Accessories

    05

    Offer

    In your region

    Contact us
    for individual

    consultation

    Contact us