Back to industrial heating
Industrie Icon

Industrial Boiler

Magno VR
250–550 kW

Forward grate firing technology
driven by hydraulic drive

  • Professional & qualified planning
  • Robust industrial design
  • Solid radiation vault
  • Recycles fuels up to 60% of water content
  • For wood chips up to M60/W60

High performance industrial boiler

Industrial heating for intensive heat demand

Step grate boiler technology is used wherever wood chips, fine wood shavings and bark with high residual water content or other biomass fuels are used. The Magno-VR 250–600 models have an integrated forward flat bed step grate.  Steady combustion on the forward grate ensures the lowest possible emission levels in the exhaust gas. Automatic de-ash occurs at the end of the grate.

  • Forward grate firing for drying, gasification and fuel combustion
  • Automatic de-ash at end of grate
  • Grate carriage with maintenance-free sliding guides
  • Forward grate firing technology driven by hydraulic drive
  • Dual-walled steel housing design to preheat the combustior air
  • Combustion control via flue gas temp. sensor, combustion chamber temp. sensor, boiler temp. sensor and Lambda sensor
  • Radiation vault in element structure for easy vault stone replacement up to Magno-VR 600
  • Ceramic lining of the combustion chamber in high temperature resistant concrete up to Magno-VR 600
  • Double-hinged combustion chamber door in front wall of combustion chamber
  • Cleaning and service door below grate
  • Dynamic combustion air control by air dampers and air flow sensors
  • Automatic, pneumatic heat exchanger cleaning
  • Suitable for wood chips EN, ISO17225-4 to P31S
  • Safety heat exchanger (optional)
  • Under grate de-ash by means of hydraulic drive (optional)
  • Flue gas recirculation (optional)
  • Central de-ash (optional)

Insides in detail

Cross section
of the Magno VR 250–550 kW

  1. Automatic, pneumatic heat exchanger cleaning
  2. Automatic flue gas gleaning
  3. Exhaust fan
  4. Primary air (2 zones)
  5. Secondary air (2 zones)
  6. Fuel supply
  7. Automatic cyclone ash extraction system in 40 l ash bin optional: 240 l or 800 l ash bin
  8. Combustion chamber door
  9. High-performance heat exchanger
  10. Combustion chamber with low-NOx design
  11. Automatic ash extraction system in 240 l ash bin optional: 800 l ash bin
  12. Rotary valve as burn-back protection
  13. Under grate de-ash system (optional)
  14. Automatic ignition
  15. Safety heat exchanger installed in boiler
View cross section

Technical
details

Nominal capacity (NC)
Fuel heat output
Minimum capacity
Electric capacity
NCV efficiency at nominal output
NCV efficiency at 30 % nominal output
GCV efficiency at nominal output
GCV at 30 % nominal output
Seasonal energy efficiency ETAs
Boiler temperature range
Measures (w x h x d)
Weight
Filling volume
Space requirement
Flue pipe diameter
Ash box volume
Water content
Flow/Return
Energy label
Unit
kW
kW
kW
kW
%
%
%
%
%
°C
mm
kg
l
mm
l
l
"
    Magno-VR 250
    Nominal capacity (NC) 250 kW
    Fuel heat output 266,5 kW
    Minimum capacity 75 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 93,8 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs 78 %
    Boiler temperature range - °C
    Measures (w x h x d) 1160 x 2610 x 3160 mm
    Weight 5100 kg
    Filling volume - l
    Space requirement 3,67
    Flue pipe diameter 200 mm
    Ash box volume 240 / 800* l
    Water content 830 l
    Flow/Return 80/65 PN16 "
    Boiler label -
    Magno-VR 300
    Nominal capacity (NC) 300 kW
    Fuel heat output 318,1 kW
    Minimum capacity 90 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 94,3 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs 79 %
    Boiler temperature range - °C
    Measures (w x h x d) 1160 x 2610 x 3160 mm
    Weight 5100 kg
    Filling volume - l
    Space requirement 3,67
    Flue pipe diameter 200 mm
    Ash box volume 240 / 800* l
    Water content 830 l
    Flow/Return 80/65 PN16 "
    Boiler label -
    Magno-VR 350
    Nominal capacity (NC) 350 kW
    Fuel heat output 369,2 kW
    Minimum capacity 105 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 94,8 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs 80 %
    Boiler temperature range - °C
    Measures (w x h x d) 1260 x 2650 x 3350 mm
    Weight 6025 kg
    Filling volume - l
    Space requirement 4,22
    Flue pipe diameter 250 mm
    Ash box volume 240 / 800* l
    Water content 1100 l
    Flow/Return 80/80 PN16 "
    Boiler label -
    Magno-VR 395
    Nominal capacity (NC) 390 kW
    Fuel heat output 409,7 kW
    Minimum capacity 120 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 95,2 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs 79 %
    Boiler temperature range - °C
    Measures (w x h x d) 1260 x 2650 x 3350 mm
    Weight 6025 kg
    Filling volume - l
    Space requirement 4,22
    Flue pipe diameter 250 mm
    Ash box volume 240 / 800* l
    Water content 1100 l
    Flow/Return 80/80 PN16 "
    Boiler label -
    Magno-VR 399
    Nominal capacity (NC) 399 kW
    Fuel heat output 419,1 kW
    Minimum capacity 135 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 95,2 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs 80 %
    Boiler temperature range - °C
    Measures (w x h x d) 1460 x 2950 x 3875 mm
    Weight 8540 kg
    Filling volume - l
    Space requirement 5,66
    Flue pipe diameter 250 mm
    Ash box volume 240 / 800* l
    Water content 1550 l
    Flow/Return 100/100 PN16 "
    Boiler label -
    Magno-VR 450
    Nominal capacity (NC) 450 kW
    Fuel heat output 470,2 kW
    Minimum capacity 135 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 95,7 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs 79 %
    Boiler temperature range - °C
    Measures (w x h x d) 1460 x 2950 x 3875 mm
    Weight 8540 kg
    Filling volume - l
    Space requirement 5,66
    Flue pipe diameter 250 mm
    Ash box volume 240 / 800* l
    Water content 1550 l
    Flow/Return 100/100 PN16 "
    Boiler label
    Magno-VR 500
    Nominal capacity (NC) 499 kW
    Fuel heat output 523,1 kW
    Minimum capacity 150 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 95,4 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs 79 %
    Boiler temperature range - °C
    Measures (w x h x d) 1460 x 2950 x 3875 mm
    Weight 8540 kg
    Filling volume - l
    Space requirement 5,66
    Flue pipe diameter 250 mm
    Ash box volume 240 / 800* l
    Water content 1550 l
    Flow/Return 100/100 PN16 "
    Boiler label -
    Magno-VR 550
    Nominal capacity (NC) 535 kW
    Fuel heat output 560,8 kW
    Minimum capacity 165 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 95,4 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs 79 %
    Boiler temperature range - °C
    Measures (w x h x d) 1460 x 2950 x 3875 mm
    Weight 8540 kg
    Filling volume - l
    Space requirement 5,66
    Flue pipe diameter 350 mm
    Ash box volume 240 / 800* l
    Water content 1550 l
    Flow/Return 100/100 PN16 "
    Boiler label -
    Magno-VR 600
    Nominal capacity (NC) 550 kW
    Fuel heat output 582,6 kW
    Minimum capacity 180 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 94,40 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs 79 %
    Boiler temperature range - °C
    Measures (w x h x d) 1460 x 2950 x 3875 mm
    Weight 8540 kg
    Filling volume - l
    Space requirement 5,66
    Flue pipe diameter 350 mm
    Ash box volume 240 / 800* l
    Water content 1550 l
    Flow/Return 100/100 PN16 "
    Boiler label -

    NCV = Net Calorific Value | GCV = Gross Calorific Value
    max. operation temperature 95 °C | max. operating pressure 6 bar | electrical supply 400 V AC, 50 Hz, 25 A fuse protection

    The right boiler for every power requirement.

    Your new heating system
    in just a few steps

    More about Hargassner

    01

    Contact us

    Contact us for get some more
    information and make an appointment!

    02

    Request

    Our team looks forward to
    hearing from you and providing
    you with professional advice.

    03

    Appoint­ment

    We will inform you in detail
    about our heating systems and the
    corresponding heating supplies
    for your biomass heating system.

    04

    Offer

    We create an energy- and
    cost-efficient offer that
    is tailored to your needs.

    In your region

    Find a
    contact person

    nearby

    Find a contact person