Step grate technology
driven by hydraulic drive

  • Professional & qualified planning
  • Robust industrial design
  • Solid radiation vault
  • For wood chips up to M60/W60
  • Recycles fuels up to 60% of water content

High-performance industrial boiler

Designed for permanent high-performance operation

With the Magno industrial systems up to 2,500 kW output, we offer an extensive range of products. The step grate boiler technology (SR) is used wherever wood chips, fine wood shavings and bark with high residual water content or other biogenic fuels are used. A forward grate step grate is used for the Magno-SR 800–2,500 models.  Automatic de-ash occurs at the end of the grate. This ensures less service on the boiler and thus saves money. The target groups for these industrial boilers range from hotels, restaurants, but also district heating schemes and large commercial to industrial enterprises. Modulating operation and highest efficiency up to 93% are possible.

  • Step grate firing (SR) for drying, gasification and fuel combustion
  • Automatic de-ash at end of grate
  • Grate carriage with maintenance-free sliding guides
  • Step grate technology driven by hydraulic drive
  • Dual-walled steel housing design to preheat the combustion air
  • Combustion control via flue gas temp. sensor, combustion chamber temp. sensor, boiler temp. sensor and Lambda sensor
  • Radiation vault with high-temperature resistant refractory bricks
  • Double-hinged combustion chamber door in front wall of combustion chamber
  • Cleaning and service door below grate
  • Dynamic combustion air control by air dampers and air flow sensors
  • Automatic, pneumatic heat exchanger cleaning
  • Suitable for wood chips EN, ISO17225-4 to P45S up to M60/W60
  • Recycles fuels up to 60% of water content
  • Safety heat exchanger (optional)
  • Under grate de-ash by means of hydraulic drive
  • Central de-ash (optional)
  • Exhaust gas recirculation (optional)

Insides in detail

Cross section
of the Magno SR 800–2500 kW

  1. Automatic, pneumatic heat exchanger cleaning
  2. Automatic flue gas cleaning
  3. Exhaust fan
  4. Primary air (2 zones)
  5. Secondary air (2 zones)
  6. Fuel supply
  7. Autom. cyclone ash extraction system in 240 l ash bin
    optional: 800 l ash bin
    standard with SR 2,000/2,500
  8. Combustion chamber door
  9. High-performance heat exchanger
  10. Combustion chamber with low-NOx design
  11. Automatic ash extraction system in 240 l ash bin
    optional: 800 l ash bin
    standard with SR 2,000/2,500
  12. Rotary valve as burn-back protection
  13. Under grate de-ash system (optional)
  14. Automatic ignition
  15. Safety heat exchanger installed in boiler
  16. Water-cooled stoker feed
View cross section

Technical
details

Nominal capacity (NC)
Fuel heat output
Minimum capacity
Electric capacity
NCV efficiency at nominal output
NCV efficiency at 30 % nominal output
GCV efficiency at nominal output
GCV at 30 % nominal output
Seasonal energy efficiency ETAs
Boiler temperature range
Measures (w x h x d)
Weight
Filling volume
Space requirement
Flue pipe diameter
Ash box volume
Water content
Flow/Return
Energy label
Unit
kW
kW
kW
kW
%
%
%
%
%
°C
mm
kg
l
mm
l
l
"
    Magno-SR 800
    Nominal capacity (NC) 850 kW
    Fuel heat output 888,2 kW
    Minimum capacity 240 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 95,7 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs 81 %
    Boiler temperature range - °C
    Measures (w x h x d) 1750 x 3700 x 5000 mm
    Weight 18000 kg
    Filling volume - l
    Space requirement 8,75
    Flue pipe diameter 400 mm
    Ash box volume 240 / 800* l
    Water content 2800 l
    Flow/Return 125/125 PN16 "
    Boiler label -
    Magno-SR 995
    Nominal capacity (NC) 995 kW
    Fuel heat output 1041,9 kW
    Minimum capacity 299 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 95,5 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs 81 %
    Boiler temperature range - °C
    Measures (w x h x d) 1750 x 3700 x 5000 mm
    Weight 18000 kg
    Filling volume - l
    Space requirement 8,75
    Flue pipe diameter 400 mm
    Ash box volume 240 / 800* l
    Water content 2800 l
    Flow/Return 125/125 PN16 "
    Boiler label -
    Magno-SR 998
    Nominal capacity (NC) 900 kW
    Fuel heat output 942,4 kW
    Minimum capacity 300 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 95,5 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs - %
    Boiler temperature range - °C
    Measures (w x h x d) 1950 x 3980 x 5070 mm
    Weight 21400 kg
    Filling volume - l
    Space requirement 9,88
    Flue pipe diameter 400 mm
    Ash box volume 240 / 800* l
    Water content 3500 l
    Flow/Return 125/125 PN16 "
    Boiler label -
    Magno-SR 999
    Nominal capacity (NC) 999 kW
    Fuel heat output 1046,1 kW
    Minimum capacity 300 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 95,5 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs - %
    Boiler temperature range - °C
    Measures (w x h x d) 1950 x 3980 x 5070 mm
    Weight 21400 kg
    Filling volume - l
    Space requirement 9,88
    Flue pipe diameter 400 mm
    Ash box volume 240 / 800* l
    Water content 3500 l
    Flow/Return 125/125 PN16 "
    Boiler label -
    Magno-SR 1200
    Nominal capacity (NC) 1200 kW
    Fuel heat output 1260,5 kW
    Minimum capacity 360 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 95,2 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs 80 %
    Boiler temperature range - °C
    Measures (w x h x d) 1750 x 3700 x 5000 mm
    Weight 18000 kg
    Filling volume - l
    Space requirement 8,75
    Flue pipe diameter 400 mm
    Ash box volume 240 / 800* l
    Water content 2800 l
    Flow/Return 125/125 PN16 "
    Boiler label -
    Magno-SR 1400
    Nominal capacity (NC) 1400 kW
    Fuel heat output 1497,3 kW
    Minimum capacity 420 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 93,5 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs - %
    Boiler temperature range - °C
    Measures (w x h x d) 1950 x 3980 x 5070 mm
    Weight 21400 kg
    Filling volume - l
    Space requirement 9,88
    Flue pipe diameter 400 mm
    Ash box volume 240 / 800* l
    Water content 3500 l
    Flow/Return 125/125 PN16 "
    Boiler label -
    Magno-SR 2000
    Nominal capacity (NC) 2000 kW
    Fuel heat output 2128,3 kW
    Minimum capacity 600 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 93,5 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs - %
    Boiler temperature range - °C
    Measures (w x h x d) 1950 x 3980 x 6700 mm
    Weight 28500 kg
    Filling volume - l
    Space requirement 13,07
    Flue pipe diameter 500 mm
    Ash box volume 240 / 800* l
    Water content 5100 l
    Flow/Return 200/200 PN16 "
    Boiler label -
    Magno-SR 2400
    Nominal capacity (NC) 2250 kW
    Fuel heat output 2406,4 kW
    Minimum capacity 675 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 93,5 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs - %
    Boiler temperature range - °C
    Measures (w x h x d) 1950 x 3980 x 6700 mm
    Weight 28500 kg
    Filling volume - l
    Space requirement 13,07
    Flue pipe diameter 500 mm
    Ash box volume 240 / 800* l
    Water content 5100 l
    Flow/Return 200/200 PN16 "
    Boiler label -
    Magno-SR 2500
    Nominal capacity (NC) 2500 kW
    Fuel heat output 2663,1 kW
    Minimum capacity 750 kW
    Electric capacity - kW
    NCV efficiency at nominal output (nn) in % 93,5 %
    NCV efficiency at 30 % nominal output (np) - %
    GCV efficiency at nominal output - %
    GCV efficiency at 30 % nominal output - %
    Seasonal energy efficiency ETAs - %
    Boiler temperature range - °C
    Measures (w x h x d) 1950 x 3980 x 6700 mm
    Weight 28500 kg
    Filling volume - l
    Space requirement 13,07
    Flue pipe diameter 500 mm
    Ash box volume 240 / 800* l
    Water content 5100 l
    Flow/Return 200/200 PN16 "
    Boiler label -

    NCV = Net Calorific Value | GCV = Gross Calorific Value
    max. operation temperature 95 °C | max. operating pressure 6 bar | electrical supply 400 V AC, 50 Hz, 25 A fuse protection

    Target group
    & possible areas of application

    The right boiler for every power requirement.

    Your new heating system
    in just a few steps

    More about Hargassner

    01

    Contact us

    Contact us for get some more
    information and make an appointment!

    02

    Request

    Our team looks forward to
    hearing from you and providing
    you with professional advice.

    03

    Appoint­ment

    We will inform you in detail
    about our heating systems and the
    corresponding heating supplies
    for your biomass heating system.

    04

    Offer

    We create an energy- and
    cost-efficient offer that
    is tailored to your needs.

    In your region

    Find a
    contact person

    nearby

    Find a contact person